Can toxic gas alarms be configured with other linkage devices?
Toxic gas alarms play a crucial role in industrial environments by automatically triggering visual and audible alerts when dangerous gases are detected. This timely warning allows personnel to take immediate action, preventing potential accidents and ensuring the safety of workers. These systems typically consist of two main components: gas detectors and gas controllers. However, to enhance safety further, many users choose to integrate additional linkage devices with their toxic gas alarm systems.
So, can toxic gas alarms be connected to other equipment? The answer is yes. By linking the alarm system with external devices such as solenoid valves or exhaust fans, the system becomes more proactive in managing gas leaks. For example, when a gas leak is detected, the controller can automatically activate an exhaust fan to reduce gas concentration or close a solenoid valve to prevent further leakage.
The installation of gas detectors depends on the density of the gas being monitored. If the gas is lighter than air, the sensor should be mounted 30 to 60 cm below the ceiling, facing downward. In contrast, if the gas is heavier than air, the detector should be placed 30 to 60 cm above the floor, also pointing downward. The gas controller, which serves as the central monitoring unit, is usually installed in a control room or an area where staff are regularly present. It is recommended to mount the controller at a height of about 1.5 meters from the ground for easy visibility.
Our gas controllers are compatible with various linkage devices. They can be connected to 220V solenoid valves or exhaust fans directly. However, for 380V equipment, such as larger exhaust fans, an external AC contactor must be used to ensure proper operation. This flexibility makes it possible to customize the system based on specific site requirements.
In addition to toxic gas alarms, combustible gas alarms can also be integrated with similar linkage devices. Many industrial facilities install these systems alongside exhaust fans and shut-off valves to minimize the risk of poisoning or explosions. The exhaust fan helps dilute the gas concentration, while the solenoid valve acts as a safety measure by cutting off the gas supply. Together, these devices significantly improve the overall safety and response capability of the system.
By properly configuring and linking these components, businesses can create a more responsive and effective gas detection system, reducing risks and protecting both people and property.