How to Solve the Abnormal Noise Problem of CLB Asphalt Heat Pump

Cause 1: Leakage of oil inlet pipes and connecting surfaces:

In response to this kind of air leakage phenomenon: we have to conduct a full range of inspections, all joints must be adjusted and checked, and then reconnected.

Cause 2: The diameter of the suction pipe is less than the specified diameter or where the diameter of the suction pipe is changed. See this item: Check and replace according to Section 3, Section 1, of this book. We give specific instructions.

Cause 3: The phenomenon that the pump and the motor are installed with different axes is also a relatively common phenomenon. According to Chapter 7, Section 1, Section 7 of this book requires re-adjustment, you can also call the manufacturer.

Reason 4: The base of the pump is not stable and vibration can be adjusted by yourself. To level the seat, the base bolt needs to be tightened.

Cause 5: Blockage of the suction pipe or filter or solidification of the medium causes congestion Countermeasures: Reduce the filter to clean and increase the heating temperature.

The above are some of the causes and analysis of abnormal noise and vibration in the CLB asphalt heat pump. The above are some of the causes and analysis of abnormal noise and vibration in the CLB asphalt heat pump. For details, please visit the website: http://. Com/ or call the factory.